Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revisionBoth sides next revision
examples:thermalcomfort [2019/07/03 11:41] – created enviadminexamples:thermalcomfort [2019/07/22 14:27] enviadmin
Line 1: Line 1:
 ====== Case Study: Thermal Comfort====== ====== Case Study: Thermal Comfort======
-{{ ::examples:placeholder.png?600 nolink |Lorem ipsum}}\\ +{{  :examples:thermal_pic.png |A simple test layout to analyze an areas microclimate and thermal comfort.}}\\
-<WRAP centeralign>//Lorem ipsum//</WRAP>+
  
-Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. +<WRAP centeralign>//Test model 200 x 190 x 30 //</WRAP>
  
 +The Thermal Comfort Case Study is a small (200 x 190 x 30 Grids) model that was used to analyze minimal invasive climate adaptation strategies to mitigate urban excess heat.
  
 ==== Download Model Files  ==== ==== Download Model Files  ====
  
-Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua +This is a simple example containing the .INX file and the .SIM file used to run the Case Study simulation.
  
 <WRAP box  90% center :en> <WRAP box  90% center :en>
 ^ Link     ^Content      ^Comments  ^ Link     ^Content      ^Comments 
-| [[http://envi-met.info/public/cases/thermalComfort/vegetation_modelfiles.zip|vegetation_modellfiles.zip]] | Model Files (Area Input File .INX plus Configuration .SIM with and without IVS)| Please extract into a folder in your workspace directory. [[filereference:output:atmosphere|→ View File Reference]]| +| [[http://envi-met.info/public/cases/thermalComfort/thermalComfort_modelfiles.zip|ThermalComfort_modelfiles.zip]] | Model Files (Area Input File .INX plus Configuration .SIM for the Plan and Optimized Plan)| Please extract into a folder in your workspace directory. [[filereference:output:atmosphere|→ View File Reference]]| 
  
 </WRAP> </WRAP>
  
  
-==== Download Sample Results ====+==== Download Sample Results Plan ==== 
 + 
 +The model results below have been calculate using the full version of ENVI-met (BUSINESS/SCIENCE).  
 + 
 +<WRAP box  90% center :en> 
 +^ Link     ^Content      ^Comments  ^  
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/atmosphere.zip|Atmosphere.zip]] |Atmosphere Data (3D |Extract to disc and View with LEONARDO |   
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/buildings.zip|Buildings.zip]] |Building Data (Static & Dynamic) (3D Facade) |Extract to disc and View with LEONARDO as Facade Data in 3D|   
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/radiation.zip|Radiation.zip]] | Radiation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D g. Excel|   
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/soil.zip|Soil.zip]] | Soil Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|   
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/solaraccess.zip|Solaraccess.zip]] | Solar Access Data (misc) |Extract to disc and view with LEONARDO as 2D (_SA_ files) or 3D Facade Data (_SAFAC_ files) or use Open...to load Solargrams (.SI files)  |  
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/surface.zip|Surface.zip]] | Surface and Surface Flux Data (2D) |Extract to disc and view with LEONARDO as 2D Map|   
 +|[[http://envi-met.info/public/cases/thermalComfort/Plan2050/vegetation.zip|Vegetation.zip]] | Vegetation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|   
 +  
 + 
 +</WRAP> 
  
-The model results below have been calculate using the full version of ENVI-met (BUSINESS/SCIENCE). The outputs generated by the free BASIC version contain much fewer data. +==== Download Sample Results Optimized Plan ====
  
 +The model results below have been calculate using the full version of ENVI-met (BUSINESS/SCIENCE). 
  
 <WRAP box  90% center :en> <WRAP box  90% center :en>
 ^ Link     ^Content      ^Comments  ^ Link     ^Content      ^Comments 
-|[[http://envi-met.info/public/cases/thermalComfort/atmosphere.zip|Atmosphere.zip]] |Atmosphere Data (3D |Extract to disc and View with LEONARDO |   +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/atmosphere.zip|Atmosphere.zip]] |Atmosphere Data (3D |Extract to disc and View with LEONARDO |   
-|[[http://envi-met.info/public/cases/thermalComfort/buildings.zip|Buildings.zip]] |Building Data (Static & Dynamic) (3D Facade) |Extract to disc and View with LEONARDO as Facade Data in 3D|   +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/buildings.zip|Buildings.zip]] |Building Data (Static & Dynamic) (3D Facade) |Extract to disc and View with LEONARDO as Facade Data in 3D|   
-|[[http://envi-met.info/public/cases/thermalComfort/radiation.zip|Radiation.zip]] | Radiation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|   +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/radiation.zip|Radiation.zip]] | Radiation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D g. Excel|   
-|[[http://envi-met.info/public/cases/thermalComfort/receptors.zip|Receptors.zip]] | Receptor Data (Text) |Extract to disc and view with any charting program e.g. Excel|   +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/soil.zip|Soil.zip]] | Soil Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|   
-|[[http://envi-met.info/public/cases/thermalComfort/soil.zip|Soil.zip]] | Soil Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|   +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/solaraccess.zip|Solaraccess.zip]] | Solar Access Data (misc) |Extract to disc and view with LEONARDO as 2D (_SA_ files) or 3D Facade Data (_SAFAC_ files) or use Open...to load Solargrams (.SI files) 
-|[[http://envi-met.info/public/cases/thermalComfort/solaraccess.zip|Solaraccess.zip]] | Solar Access Data (misc) |Extract to disc and view with LEONARDO as 2D (_SA_ files) or 3D Facade Data (_SAFAC_ files) or use Open...to load Solargrams (.SI files) +
 |[[http://envi-met.info/public/cases/thermalComfort/surface.zip|Surface.zip]] | Surface and Surface Flux Data (2D) |Extract to disc and view with LEONARDO as 2D Map|   |[[http://envi-met.info/public/cases/thermalComfort/surface.zip|Surface.zip]] | Surface and Surface Flux Data (2D) |Extract to disc and view with LEONARDO as 2D Map|  
-|[[http://envi-met.info/public/cases/thermalComfort/vegetation.zip|Vegetation.zip]] | Vegetation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|  +|[[http://envi-met.info/public/cases/thermalComfort/Opt2050/vegetation.zip|Vegetation.zip]] | Vegetation Data (3D) |Extract to disc and view with LEONARDO as 2D or 3D Map|