Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
apps:updates [2026/09/23 16:11] – enviadminapps:updates [2026/09/23 16:20] (current) – enviadmin
Line 22: Line 22:
   * **Wind Comfort:** Multi-direction wind-field analysis with exceedance probabilities, graded against the NEN 8100, Lawson and Davenport standards. ** EXCLUSIVE TO BUSINESS LICENSE TIER**   * **Wind Comfort:** Multi-direction wind-field analysis with exceedance probabilities, graded against the NEN 8100, Lawson and Davenport standards. ** EXCLUSIVE TO BUSINESS LICENSE TIER**
   * **Surrounding-area presets:** Characterise the urban context upstream for each model domain border with ready-made urban-climate-zone and land-cover presets, from open water and countryside through to dense city cores.   * **Surrounding-area presets:** Characterise the urban context upstream for each model domain border with ready-made urban-climate-zone and land-cover presets, from open water and countryside through to dense city cores.
-  * **Absolute air temperature** is now the primary temperature in result files, listed ahead of potential temperature, and air pressure is referenced to the actual site elevation rather than a fixed standard value. Scripts that read result variables by position need to be updated (see note above).+  * **Absolute air temperature** is now the primary temperature in result files, listed ahead of potential temperature, and air pressure is referenced to the actual site elevation rather than a fixed standard value. Scripts that read result variables by position need to be updated.
   * **Building indoor climate & air-conditioning heat:** Set an indoor temperature per building and choose whether the heat its air conditioning removes is released into the surrounding air, letting you study the outdoor warming that cooling demand produces. Allow natural ventilation of buildings based on thermal indoor/outdoor thresholds and usage periods.    * **Building indoor climate & air-conditioning heat:** Set an indoor temperature per building and choose whether the heat its air conditioning removes is released into the surrounding air, letting you study the outdoor warming that cooling demand produces. Allow natural ventilation of buildings based on thermal indoor/outdoor thresholds and usage periods. 
   * **Spin-up of the model:** ENVI-met now runs a spin-up phase for soils, materials etc. that automatically derives their initial temperatures, replacing the previous manual soil temperature input.   * **Spin-up of the model:** ENVI-met now runs a spin-up phase for soils, materials etc. that automatically derives their initial temperatures, replacing the previous manual soil temperature input.